Xem mẫu
TECHNICALDATA
Product Features:
! Nominal Velocity of Propagation at 100 MHz*: 75% ! Featuring airESTM technology
! Patented impedance matching for zero-bit errors ! Manufactured with lead-free materials Specifications:
Conductor: Insulation: Separator: Jacket:
Nominal OD:
24 AWG solid bare copper All 4 pairs 100% FEP Fluoropolymer
Non-lead, flame retardant PVC
.208” (5.3 mm)
TrueNet AirES
4 Pair Plenum Cable Patent Number 6153826
Mechanical Characteristics Bend Radius
During Installation: 8 X O.D. Installed: 4 X O.D. Pull Tension: 25# (110N)
Thermal Characteristics
Transport and Storage: -20oC to 75oC Installation: 4oC to 50oC Operation: -20oC to 75oC
Maximum Average OD*: .212” (5.4 mm) Compliances:
UL Subject 444
(UL)-C(UL) Type CMP ICEA S-90-661
NEC 800 Type CMP
ETL Verified TIA/EIA 568-B.2-1 Cat 6 Horizontal Cable Requirements ISO/IEC 11801 Class E
Common Applications:
4/16 Mb/s Token Ring (IEEE 802.5) 10BASE-T (IEEE 802.3)
100 Mb/s TP-PMD
Broadband & Baseband Video 100BASE-T (“Fast Ethernet”) 100BASE-T4 (“Fast Ethernet”) 100BASE-TX (“Fast Ethernet”) 100VG-Any LAN (IEEE 802.12) 52/155 Mb/s ATM (ATM Forum) 622 Mb/s ATM (ATM Forum) 1000BASE-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA) 1.2 Gb/s ATM (ATM Forum)
77 Channel Broadband Video
Electrical Characteristics: Conductor DC Resistance @ 20oC (Max): DC Resistance Unbalance (Max):
Mutual Capacitance @ 20oC (Max): Operating Temperature (Max): Operating Voltage (Max):
Worst Case Cable Skew:
Ordering Information:
28.6 Ω/1000 ft (9.38 Ω/100 m) 2%
17 pF/ft (5.6nF/100 m) 75oC
300 VDC
21 ns/100 m
PRODUCT NUMBER
NO. OF JACKET PAIRS COLOR
WEIGHT PACKAGING LBS/KFT KG/KM
TN6SP-XX02 4
TN6SP-XXRB 4
Select 30
Select 32
45 1,000` Reel
48 1,000` Reel-in-a-Box
NOTES: XX = Jacket color - BL = Blue, WT = White, GY = Gray, GN = Green, YL = Yellow, call for additional color options Packaging - Replace “02” for the following footages: 04=2,000’, 05=2,500’, call for additional packaging options
* VOP is measured on twisted pairs, value is 3 - 5% higher measured on a single insulated conductor * It is recommended that maximum average OD be used for conduit fill calculations
23-MAR-04 Rev. 3
P h o n e : 8 0 0 . 7 7 5 . 5 7 6 6
MK031-07
W e b : w w w . K R O N E . c o m
TECHNICALDATA Electrical Characteristics (Con’t.)
IMPEDANCE FREQ Ohms
MHz
Input Characteristic Typical Typical
ATTENUATION dB/100m
Typical Spec
RETURN LOSS dB
Typical Spec
ATTENUATION-TO-NEXT RATIO Pair-To-Pair Power Sum dB/100m dB/100m
Typical Spec Typical Spec
1 100 +/- 5
4 100 +/- 5
8 100 +/- 5
10 100 +/- 5
16 100 +/- 5
20 100 +/- 5
25 100 +/- 5
31.25 100 +/- 5
62.5 100 +/- 5
100 100 +/- 5
155 100 +/- 5
200 100 +/- 5
250 100 +/- 5
300 100 +/- 5
350 100 +/- 5
400 100 +/- 5
550 100 +/- 8
100 +/- 5
100 +/- 3
100 +/- 3
100 +/- 3
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
100 +/- 2
1.6 2.0 30.6
3.4 3.8 34.9
4.8 5.3 40.1
5.4 6.0 38.0
6.9 7.6 41.3
7.7 8.5 38.8
8.7 9.5 40.9
9.8 10.7 40.9
14.1 15.4 41.2
18.0 19.8 40.2
22.9 25.2 35.8
26.4 29.0 36.4
29.7 32.8 34.5
33.0 31.5
35.9 32.4
38.8 31.5
47.1 24.4
20.0 93.5 72.3
23.0 82.8 61.5
24.5 80.2 55.4
25.0 74.7 53.3
25.0 69.8 48.7
25.0 67.9 46.3
24.3 65.3 43.8
23.6 63.7 41.2
21.5 55.0 32.0
20.1 52.6 24.5
18.8 39.1 16.3
18.0 34.6 10.8
17.3 29.1 5.5
25.0
22.2
17.6
3.5
87.4 70.3
77.1 59.5
72.3 53.4
68.0 51.3
64.6 46.7
61.9 44.3
59.3 41.8
56.7 39.2
49.3 30.0
44.6 22.5
34.1 14.3
28.4 8.8
24.4 3.5
19.2
14.9
11.5
-
FREQ MHz
NEXT
Pair-To-Pair Power Sum dB/100m dB/100m
ELFEXT
Pair-To-Pair Power Sum dB/100m dB/100m
Typical
1 95.2
4 86.1
8 85.0
10 80.1
16 76.7
20 75.7
25 74.1
31.25 73.5
62.5 69.2
100 70.7
155 62.2
200 61.1
250 59.0
300 58.2
...
- tailieumienphi.vn
nguon tai.lieu . vn