Xem mẫu
TECHNICAL SPECIFICATION
Central Tube,
Single Jacket/non-Armor Cable [10Gigabit Ethernet MMF ]
1. SCOPE
1.1 Application
This specification covers the general requirements for fiber optic telecommunication cables used for indoor/outdoor application.
1.2 Cable Description
1) PE Single Jacket
10 Gigabit Ethernet Multi mode color coded fibers, filled central tube, glass yarn as non-metallic armor, water swellable yarn and outer PE jacket
2) Low Smoke Zero Halogen(LSZH) Single Jacket
10 Gigabit Ethernet Multi mode color coded fibers, filled central tube, glass yarn as non-metallic armor, water swellable yarn and outer LSZH jacket
2. OPTICAL FIBER
The optical geometrical and mechanical performance of the optical fiber shall be in accordance with Table 1 below.
Table 1. The Characteristics of the 50um Multi Mode Fiber(10 Gb-E)
ITEMS
Attenuation
10 Gigabit Ethernet Operational Length
Effective Modal Bandwidth
Numerical Aperture
Core Diameter
Core Non-circularity
Cladding Diameter
Cladding Non-circularity
Core/Cladding Concentricity Error
Coating Diameter
Proof Test
UNITS
dB/km
m
MHz.km
-
µm
%
µm
%
µm
µm
kpsi
SPECIFICATION
≤ 3.0 at 850nm ≤ 1.0 at 1300nm
≥ 300 at 850nm
≥ 2000 at 850nm
0.20 ± 0.015
50 ± 3.0
≤ 6.0
125 ± 2.0
≤ 2.0
≤ 3.0
245 ± 15
≥ 100
3. CABLE CONSTRUCTION
The construction of the cable shall be in accordance with Table 3 below.
Table 3. Construction of the Cable
ITEMS DESCRIPTION
Number of Fibers 2 ~ 24
Type of Fiber
Loose Buffer Tube
Filling Compound in Central Tube
Water Blocking Material
Ripcord
Strength Member
50/125um Multi Mode (OM-3 type fiber)
PBT (Polybutylene Terephthalate)
Thixotropic Jelly Compound
Water Swellable Yan or Water Swellable Tape (if necessary)
One ripcord
Glass Yarn or Aramid Yarn
Outer Jacket
Material
Thickness
Black PE or LSZH
Nom. 1.0mm
4. FIBER IDENTIFICATION
The color code of the central tube and the individual fibers within central tube shall be in accordance with Table 4 below.
Table 4. The Color Code of the Individual Fibers
No. of Fibers
1 2 3 4 5 6 7 8 9 10 11
12
Color No. of Fibers
Blue 13 Orange 14 Green 15 Brown 16 Grey 17 White 18 Red 19 Black 20 Yellow 21 Violet 22 Pink 23
Aqua 24
Color
Orange / Single Ring Stripe* Green / Single Ring Stripe* White / Single Ring Stripe* Yellow / Single Ring Stripe* Pink / Single Ring Stripe* Aqua / Single Ring Stripe*
Orange / Double Ring Stripes** Green / Double Ring Stripes** White / Double Ring Stripes** Yellow / Double Ring Stripes** Pink / Double Ring Stripes**
Aqua / Double Ring Stripes**
5. PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TESTS
5.1 Temperature Range
For the cables covered by this specification, the following temperature ranges apply: -. Operation : -20°C to +60°C
-. Installation : -5°C to +50°C -. Storage/Shipping : -25°C to +70°C
5.2 Mechanical and Environmental Performance of the Cable
The mechanical and environmental performance of the cable shall be in accordance with Table 5 below. Unless otherwise specified, all attenuation measurements required in this section shall be performed at 1300nm for multi mode fiber.
Table 5. The Mechanical and Environmental Performance of the Cable
ITEMS
Tensile Loading And Bending Test
Compressive Loading Resistance Test
TEST METHOD AND ACCEPTANCE CRITERIA
# Test method: TIA/EIA-FOTP-33
-. Mandrel diameter: 30D (D = cable diameter) -. Tensile load: 1,800N for 1 hour
# Acceptance Criteria
-. Fiber strain: Less than 60% of the fiber proof strain -. Attenuation increment: ≤ 0.30 dB at 1300nm
# Test method: TIA/EIA-FOTP-41 -. Applied load: 2200 N/100mm
-. Duration of loading: 10 minutes # Acceptance Criteria
-. Attenuation Increment: ≤ 0.20 dB
after the completion of the test
Table 5. The Mechanical and Environmental Performance of the Cable (continued)
ITEMS
Repeated Impact Test
Cyclic Flexing Test
Cable Twist Test
Temperature Cycling Test
TEST METHOD AND ACCEPTANCE CRITERIA
# Test method: TIA/EIA-FOTP-25 -. Height of impact: 150mm
-. Drop hammer mass: 2.0kg
-. No. of impact cycles: 20 cycles # Acceptance Criteria
-. Attenuation Increment: ≤ 0.20 dB
after the completion of the test -. No jacket cracking and fiber breakage
# Test method: TIA/EIA-FOTP-104
-. Sheave diameter: 20D (D = cable diameter) -. No. of flexing cycles: 25 cycles
-. Flexing speed: 30 cycles/minute # Acceptance Criteria
-. Attenuation Increment: ≤ 0.20 dB
-. No jacket cracking and fiber breakage # Test method: TIA/EIA-FOTP-85
-. Cable length twisted: 2m
-. No. of twist cycles: 10 cycles -. Twist angle: ± 180˚
# Acceptance Criteria
-. Attenuation Increment: ≤ 0.20 dB
-. No jacket cracking and fiber breakage # Test method: TIA/EIA-FOTP-3
-. Temperature cycling schedule
: 23°C → -20°C → 65°C → -20°C → 65°C -. Soak time at each temperature: 24hours
-. No. of cycles: 2 cycles # Acceptance Criteria
-. Attenuation increment:
⋅ Average ≤ 0.20 dB/km ⋅ Maximum ≤ 0.30 dB/km
...
- tailieumienphi.vn
nguon tai.lieu . vn