TECHNICAL SPECIFICATION
Central Tube
Single Jacket/ Single Armor Cable 50/125um, 10Gigabit Ethernet MMF P/N N008CTSARMLZH050U
1. SCOPE
1.1 Application
This specification covers the general requirements for fiber optic telecommunication cables used for outdoor application.
1.2 Cable Description
Low Smoke Zero Halogen (LSZH) Single Jacket/ Single Armor, Multi mode color-coded fibers, filled central tube, water blocking tape, corrugated steel tape, metallic external strength member and outer LSZH jacket
2. OPTICAL FIBER
The optical geometrical and mechanical performance of the optical fiber shall be in accordance with Table 1 and Table 2 below.
Table 1. The Characteristics of the 50um Multi Mode Fiber(10 Gb-E)
ITEMS
Attenuation
10 Gigabit Ethernet Operational Length
Effective Modal Bandwidth
Numerical Aperture
Core Diameter
Core Non-circularity
Cladding Diameter
Cladding Non-circularity
Core/Cladding Concentricity Error
Coating Diameter
Proof Test
UNITS
dB/km
m
MHz.km
-
µm
%
µm
%
µm
µm
kpsi
SPECIFICATION
≤ 3.0 at 850nm ≤ 1.0 at 1300nm
≥ 300 at 850nm
≥ 2000 at 850nm
0.20 ± 0.015
50 ± 3.0
≤ 6.0
125 ± 2.0
≤ 2.0
≤ 3.0
245 ± 15
≥ 100
3. CABLE CONSTRUCTION
The construction of the cable shall be in accordance with Table 2 below.
Table 2. Construction of the Cable ITEMS
Number of Fibers
Type of Fiber
DESCRIPTION
8 Core
50 Multi Mode
Loose Buffer Tube
Filling Compound in Central Tube
Water Blocking Material
Rip Cord
Strength Member
PBT (Polybutylene Terephthalate)
Thixotropic Jelly Compound
Water Swellable Tape
Aramid ripcord
(To provide easy cable entry)
Two Galvanized Steel Wire (180 degree apart)
Armor
Outer Jacket
Material
Thickness
Material
Thickness
Steel Tape with Plastic Coating on Both Sides
Nom. 0.15mm (Steel Tape) Nom. 0.05mm (Plastic Coating) Black LSZH
Nom. 2.5mm
4. FIBER IDENTIFICATION
The color code of the central tube and the individual fibers within central tube shall be in accordance with Table 4 below.
Table 3. The Color Code of the Individual Fibers
No. of Fibers 1 2 3 4 5 6 7 8 9 10 11
12
Color No. of Fibers Blue 13 Orange 14 Green 15 Brown 16
Grey 17 White 18 Red 19 Black 20 Yellow 21 Violet 22 Pink 23
Aqua 24
Color
Orange / Single Ring Stripe* Green / Single Ring Stripe* White / Single Ring Stripe* Yellow / Single Ring Stripe* Pink / Single Ring Stripe* Aqua / Single Ring Stripe*
Orange / Double Ring Stripes** Green / Double Ring Stripes** White / Double Ring Stripes** Yellow / Double Ring Stripes** Pink / Double Ring Stripes** Aqua / Double Ring Stripes**
5. PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TESTS
5.1 Temperature Range
For the cables covered by this specification, the following temperature ranges apply: -. Operation : -20°C to +60°C
-. Installation : -5°C to +50°C -. Storage/Shipping : -25°C to +70°C
5.2 Mechanical and Environmental Performance of the Cable
The mechanical and environmental performance of the cable shall be in accordance with Table 4 below. Unless otherwise specified, all attenuation measurements required in this section shall be performed at 1300nm for multi mode fiber (MM).
Table 4. The Mechanical and Environmental Performance of the Cable
ITEMS
Tensile Loading And Bending Test
Compressive Loading Resistance Test
Repeated Impact Test
Cyclic Flexing Test
TEST METHOD AND ACCEPTANCE CRITERIA
# Test method: TIA/EIA-FOTP-33
-. Mandrel diameter: 30D (D = cable diameter) -. Tensile load: 1,800N for 1 hour
# Acceptance Criteria
-. Fiber strain: Less than 60% of the fiber proof strain -. Attenuation increment: ≤ 0.30 dB at 1300nm (MM)
≤ 0.20 dB at 1550nm (SM)
# Test method: TIA/EIA-FOTP-41 -. Applied load: 4400 N/100mm
-. Duration of loading: 10 minutes # Acceptance Criteria
-. Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM)
after the completion of the test # Test method: TIA/EIA-FOTP-25
-. Height of impact: 150mm
-. Drop hammer mass: 2.0kg
-. No. of impact cycles: 20 cycles # Acceptance Criteria
-. Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM)
after the completion of the test -. No jacket cracking and fiber breakage
# Test method: TIA/EIA-FOTP-104
-. Sheave diameter: 20D (D = cable diameter) -. No. of flexing cycles: 25 cycles
-. Flexing speed: 30 cycles/minute # Acceptance Criteria
-. Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM)
-. No jacket cracking and fiber breakage
Table 4. The Mechanical and Environmental Performance of the Cable (continued)
ITEMS
Cable Twist Test
Temperature Cycling Test
Water Penetration Test
Flammability Test
(LSZH Jacket Cable only)
TEST METHOD AND ACCEPTANCE CRITERIA
# Test method: TIA/EIA-FOTP-85 -. Cable length twisted: 2m
-. No. of twist cycles: 10 cycles -. Twist angle: ± 180˚
# Acceptance Criteria
-. Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM)
-. No jacket cracking and fiber breakage # Test method: TIA/EIA-FOTP-3
-. Temperature cycling schedule
: 23°C → -20°C → 65°C → -20°C → 65°C -. Soak time at each temperature: 24hours
-. No. of cycles: 2 cycles # Acceptance Criteria
...