IMPEDANCE TRANSFORMERS In the preceding chapter, several techniques were considered to match a given load impedance at a ®xed frequency. These techniques included transmission line stubs as well as lumped elements. Note that lumped-element circuits may not be practical at higher frequencies. Further, it may be necessary in certain cases to keep the re¯ection coef®cient below a speci®ed value over a given frequency band. This chapter presents transmission line impedance transformers that can meet