Xem mẫu

Operating Instructions IWABO VIllA-s1x Pellets heating for houses Naturenergi IwaboAB Björnnäsvägen 25, sE-823 30 Kilafors, sweden Tel +46(0)278-63 64 30, Fax +46(0)278-63 64 40 www.naturenergi.se Iwabo Villa-s1x Iwabo Villa-s1x Innehåll PREFACE.................................................................................................................................4 Warning symbols and texts................................................................................................4 SAFETY ...................................................................................................................................5 INSTALLATION........................................................................................................................6 CONTROLS .............................................................................................................................7 START-UP AND OPERATION.................................................................................................8 Feeding of pellets..............................................................................................................8 Normal start / Heating cycle (with factory-settings)...........................................................8 SETTINGS................................................................................................................................9 Adjustment of burner.........................................................................................................9 Change of times, dampers etc. .......................................................................................10 ADJUSTMENT OF CONTROL ELECTRONICS ....................................................................11 Functions P1-P5...............................................................................................................11 Reading of potentiometer values......................................................................................11 Adjustment table..............................................................................................................12 TUNING OF BURNER ...........................................................................................................12 SAFETY SYSTEMS AGAINST BURN-BACK ......................................................................13 MAINTENANCE.....................................................................................................................13 Cleaning/Ash handling:....................................................................................................13 Check/cleaning of photocell:............................................................................................14 MAINTENANCE CHART .......................................................................................................14 TROUBLE-SHOOTING..........................................................................................................15 Plant has stopped; plant does not start; etc. ...................................................................15 CIRCUIT DIAGRAM...............................................................................................................17 DESCRIPTION OF FUNCTION .............................................................................................19 Light-emitting diodes (LED).............................................................................................19 TIPS FOR FINE-TUNING.......................................................................................................20 CHECKS AFTER INSTALLATION.........................................................................................21 Spare parts for 20 kW 95099 pellets burner...........................................................................23 Spare parts for 95088, 95089 pellets feed augers.................................................................25 TECHNICAL DATA ................................................................................................................26 DECLARATION OF CONFORMITY / w standards ..............................................................27 GUARANTEE CERTIFICATE................................................................................................28 INSTALLATION OF PELLETS AUGER in one-week storage bin.......................................29 ASSEMBLY OF 2,5 METER IWABO AUGER.......................................................................32 Iwabo Villa-s1x PREFACE The pellets-burning equipment IWABO Villa-s1x is designed for burning wood pellets after the equipment has been docked onto a heating boiler. The pellets-burning equipment IWABO Villa-s1x must not be red with any other combustible materials. The pellets-burning equipment IWABO Villa-s1x is to be in -stalled in a boiler room that has been approved for this purpose by the local authorities. WARNING SYMBOL This warning symbol will be shown in these operating instruc-tions to make you aware of possible hazards if you do not follow the instructions. There are two kinds of warning sym-bols and texts used in this manual: WARNINGwarns you of dangerous situations if neces-sary measures are not being taken. NOTEwarns you of less than safe ways or procedures that might lead to safety hazards or material damage. Iwabo Villa-s1x SAFETY • The plant must not be test-run or put into operation until it has been connected to a heating boiler and the smoke has a free pas-sage out into the open air through a ue gas duct or chimney. The boiler’s ue gas damper must not be closed because of the risk of blow-ups when the weather is changing. For this reason, a counter-draught valve should be installed to ensure even draught in the boiler and prevent burn-backs. The negative pressure in the boiler’s re chamber should be at least 0.05-0.06 Hpa (0.5-0.6 mm VP). • The chimney should be at least 125 mm in diameter and at least 6 m long. • The pellets must be kept in a moisture-free and ventilated stora-ge. The plant is intended to be red only with wood pellets 6 – 10 mm in diameter. NOTEAlways wear mouth protection when handling pellets. • The boiler room where the pellets-burning equipment is instal-led must comply with the provisions stipulated by the local re protection authorities. WARNING Only a qualied electrician is allowed to carry out the electrical installation work. • Modications, changes or reconstruction of the pellets-burning equipment must not be carried out without the manufacturer’s consent in writing. • spare parts that are not original spare parts and do not meet the manufacturer’s specications may affect the safety of the pellets-burning equipment and must, therefore, not be tted without the manufacturer’s consent in writing. • The pellets-burning equipment must not be installed in an envi-ronment where there might be a re hazard. • Combustible material must not be kept in the vicinity of the plant. • No welding work may be carried out on the plant until the power supply has been cut off and the circuit board has been removed. • Do not open any hatch on the boiler during operation. ... - tailieumienphi.vn
nguon tai.lieu . vn