Xem mẫu

Maintenance Serial Control (XON XOFF) Maintenance Serial Port Flow Control (XON XOFF) Software Version CPC-S and CPC-M, Version 1 0 and Address (0 or Description Use this address to determine whether the DBS 824 system will control the flow of data between it and the device connected to the Maintenance serial port (if activated in this address) is a software switch that will temporarily stop the flow of data when the device s memory buffer receives more data than it can process and resume the flow when the buffer empties should be deactivated (default setting) if a flow control mechanism is present elsewhere in the interface (i e , in the printer or RTS and CTS lines) A flow control mechanism should always be present in order to prevent data from being lost during transmission (0 or off (824 software does not control data flow) 1 on (824 software controls data flow) Notes Buffer The size of the DBS 824 buffer for maintenance data is 1 000 bytes This is the maximum amount of data that the system can hold while the device is emptying its buffer l-76 DBS 824-l O-400 Issued Automatic Night 1 Mode Start Time System Timers Automatic Night 1 Mode Start Time Software Version CPC-S and CPC-M, Version 1 0 and higher Address Description This option sets a time for the DBS 824 to automatically switch from ‘Day to ‘Night 1’ mode This program uses the time format. Programming To set the automatic Night 1 mode start time Night 1 Mode Start Time (in format) To disable the automatic Night 1 mode start time CONF ON/OFF Related Programming Time Setting, Automatic Day Mode Start Time Automatic Night 2 Mode Start Time Notes System Clock Automatic Night 1 start time depends on the accuracy of the DBS 824 clock issued DBS 824-l O-400 l-77 Attendant Hold Recall Timer for CO Calls Attendant Hold Recall Timer for CO Calls Software Version CPC-S and CPC-M, Version 1 0 and higher Address Description This timer determines how long a trunk call can be held by the attendant(s) before it will recall Programming Recall Timer see table below) Table timer for attendant-held CO calls Number Value 0 No recall 1 20 seconds I 40 seconds 60 seconds 80 seconds 100 seconds 6 120 seconds 7 140 seconds 8 160 seconds 9 180 seconds 10 200 seconds 11 I 220 seconds I 12 240 seconds Related Programming Attendant Hold Recall Timer for Intercom calls l-78 DBS 824-10-400 Issued Extension Hold Recall Timer for CO Calls Extension Hold Recall Timer for CO Calls Software Version CPC-S and CPC-M, Version 1 0 and higher Address Description This timer determines how long a call will be held by an extension before it will recall Programming Recall Timer (Default=7 see the following table) Table I 8 Recall values for extension-held CO 11 220 seconds 12 240 seconds Related Programming Extension Hold Recall for Intercom Calls Attendant Transfer Recall Timer for CO Calls Attendant Transfer Recall Timer for CO Calls Software Version CPC-S and CPC-M, Version 1 0 and higher Address (0-12)# Description When an attendant transfers a trunk call to an extension or hunt group, the transferred call will recall to the attendant if it is not answered This timer determines how long a transferred call will go unanswered before it recalls Programming Recall Timer (Default=1 see the following table) Table Recall timer values for transferred CO 11 220 seconds 12 240 seconds ... - tailieumienphi.vn
nguon tai.lieu . vn