Xem mẫu

 SINAMICS V20 Inverter

___________________
Preface
1
___________________
Safety instructions

SINAMICS
SINAMICS V20 Inverter

2
___________________
Mechanical installation
3
___________________
Electrical installation
4
___________________
Commissioning
5
___________________
Parameter list

Getting Started

6
___________________
Fault and warning codes
7
___________________
Technical specifications
8
___________________
Ordering data

07/2012
A5E03728127

Legal information
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE
indicates that an unintended result or situation can occur if the relevant information is not taken into account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.

Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.

Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.

Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY

A5E03728127
Ⓟ 07/2012 Technical data subject to change

Copyright © Siemens AG 2012.
All rights reserved

Preface
Purpose of this manual
This manual provides you with information about the proper installation, quick commissioning
and basic operation of SINAMICS V20 inverters.

SINAMICS V20 user documentation components
Document

Product

Language

SINAMICS V20 Inverters

Chinese (available as a printed
manual)

Inverter system
Operating Instructions

English
Getting Started
Options

SINAMICS V20 Inverters

Chinese - English bilingual

Parameter Loaders

1)

Chinese - English bilingual

2)

Product Information
Product Information

Dynamic Braking Modules

Chinese - English bilingual

Product Information

External Basic Operator Panels (BOPs)

Chinese - English bilingual

Product Information

BOP Interface Modules

Chinese - English bilingual

Product Information

Screening Plate Kits

Chinese - English bilingual

Replacement Fans

Chinese - English bilingual

Spare parts 2)
Product Information
1)

The Getting Started is included in the delivery of the inverter.

2)

The Product Information is included in the delivery of individual options or spare parts.

Technical support
Country

Hotline

China

+86 400 810 4288

Germany

+49 (0) 911 895 7222

Italy

+39 (02) 24362000

Brazil

+55 11 3833 4040

India

+91 22 2760 0150

Korea

+82 2 3450 7114

Turkey

+90 (216) 4440747

USA

+1 423 262 5710

Further service contact information: Support contacts
(http://support.automation.siemens.com/WW/view/en/16604999)

For ordering information, see Chapter "Ordering data (Page 65)".

SINAMICS V20 Inverter
Getting Started, 07/2012, A5E03728127

3

Preface

SINAMICS V20 Inverter

4

Getting Started, 07/2012, A5E03728127

Table of contents
Preface ...................................................................................................................................................... 3
1

Safety instructions ..................................................................................................................................... 7

2

Mechanical installation............................................................................................................................. 13
2.1
2.2

3

Mounting orientation and clearance.............................................................................................13
Mounting ......................................................................................................................................14

Electrical installation ................................................................................................................................ 19
3.1
3.2

4

Typical system connections .........................................................................................................19
Terminal description.....................................................................................................................21

Commissioning ........................................................................................................................................ 23
4.1
4.1.1
4.1.2
4.1.3
4.1.4

The built-in Basic Operator Panel (BOP).....................................................................................23
Introduction to the built-in BOP ....................................................................................................23
Inverter menu structure................................................................................................................25
Viewing inverter status.................................................................................................................26
Editing parameters.......................................................................................................................26

4.2

Setting the 50 / 60 Hz selection menu .........................................................................................28

4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5

Quick commissioning ...................................................................................................................29
Structure of the setup menu.........................................................................................................29
Setting motor data........................................................................................................................30
Setting connection macros...........................................................................................................32
Setting application macros...........................................................................................................44
Setting common parameters........................................................................................................47

4.4

Restoring to defaults ....................................................................................................................48

5

Parameter list .......................................................................................................................................... 49

6

Fault and warning codes.......................................................................................................................... 59

7

Technical specifications........................................................................................................................... 61

8

Ordering data........................................................................................................................................... 65

SINAMICS V20 Inverter
Getting Started, 07/2012, A5E03728127

5

nguon tai.lieu . vn